Kamolov, Jurabek and Samiev, Kamoliddin (2025) Temperature distribution in a panel-radiant heating system. International Journal of Science and Research Archive, 14 (2). pp. 1617-1625. ISSN 2582-8185
![IJSRA-2025-0560.pdf [thumbnail of IJSRA-2025-0560.pdf]](https://eprint.scholarsrepository.com/style/images/fileicons/text.png)
IJSRA-2025-0560.pdf - Published Version
Available under License Creative Commons Attribution Non-commercial Share Alike.
Abstract
In this study, a computer model was developed in Comsol Multiphysics to determine and evaluate the temperature distribution in a panel-radiant heating system with a heated floor. A panel-radiant heating system consisting of a concrete layer with dimensions of 4 × 3.3 × 0.1 m³ was selected, and copper pipes with an inner diameter of 2 cm and total lengths of 64.84 m and 64.24 m were installed within this volume. Water was used as the heat carrier. The calculations revealed that in the second configuration, the temperature distribution on the surface of the panel-radiant heated floor system is relatively uniform and does not exceed the required value.
Item Type: | Article |
---|---|
Official URL: | https://doi.org/10.30574/ijsra.2025.14.2.0560 |
Uncontrolled Keywords: | Panel-Radiant Heating System; Thermal Properties; Analytical Solution; Temperature Distribution; Thermal Resistance |
Depositing User: | Editor IJSRA |
Date Deposited: | 15 Jul 2025 17:35 |
Related URLs: | |
URI: | https://eprint.scholarsrepository.com/id/eprint/903 |